DR300 Operator Manual
39
[6] Setting Default Value
To enter this mode, power on printer while holding down <FEED> and <LINE> keys
simultaneously.
Press <FEED> and <LINE> keys when power on printer, buzzer sounds, and press
<LINE> key to move cursor to [YES]. Confirm by pressing <FEED> key.
[7] Setting Service Mode (Default & Service Mode)
To enter this mode, power on printer while holding down <FEED> and <LINE> keys
simultaneously.
Press <FEED> and <LINE> keys while power on printer,
buzzer sounds and press <LINE> key to move cursor to
[NO]. Confirm by pressing <FEED> key.
Setting sensor level
<LINE> key : proceed to pitch
adjustment setting.
<FEED> key : selection of sensor
level and threshold
level.
DEFAULT
NO
YES
DEFAULT
COMPLETE
DEFAULT
NO
YES
SERVICE
MODE
Tctr [0.0v]
TH [0.0
v]
SERVICE
LVL SET
FEED key
FEED key
FEED key
LINE key