SATO MB410i Service Manual Page 70

  • Download
  • Add to my manuals
  • Print
  • Page
    / 158
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 69
Unit 4: Standard Command Codes
“i” Programming Reference
4-40 PN: 9001158B
SYSTEM COMMANDS
BUZZER ACTIVATION
FUNCTION
Activate/Deactivate buzzer. This command can be used on MB4i series only.
FORMAT
<ESC>BU
Parameter
a = 0 : deactivated
1 : activated
EXAMPLE
<A>
<BU>1
<Z>
OUTPUT
This command does not result in printer output.
NOTES
Place this command between <A>Start code and <Z> End code.
This command cannot be used in combination with other commands
Check the setting currently valid on the test print.
Repower the printer to make the selection valid.
Hexadecimal code:
ESC: <1B>16
BU: <42>16<55>16
Parameter: a
Initial value: 0
Valid range and term of command:
When printer is powered OFF: The set parameter is maintained.
Valid range in item: The set parameter is valid until overrridden by a new value.
Valid range between items: The set parameter is valid until overridden until overridden by a new value.
Page view 69
1 2 ... 65 66 67 68 69 70 71 72 73 74 75 ... 157 158

Comments to this Manuals

No comments