Unit 4: Standard Command Codes
E/Pro Programming Reference
4-85 PN: 9001096E
PRINT AREA, STANDARD, OR PRINT AREA, ENLARGEMENT
FUNCTION
Specifies the print area to be standard height of 178 mm or enlarged to 356 mm.
FORMAT
<ESC>AR Standard print area
<ESC>AX Enlarged print area
Place after <ESC>A within the data stream.
EXAMPLE
<ESC>A
<ESC>AR
<ESC>Z
OUTPUT
(4-53)
NOTES
This command changes the print area of pitch direction.
Insert this command after Start of Data Transmission (<ESC>A). To return to the standard print area,
power off the printer to cancel the command.
Refer to Appendix: Reference Table 39 for additional information.
Comments to this Manuals