Unit 4: Standard Command Codes
E/Pro Programming Reference
4-106 PN: 9001096E
SENSOR TYPE
FUNCTION
To select a label sensing method for a print job.
FORMAT
<ESC>IGa
a = 0: Reflective (Eye-Mark) sensor
1: Gap (transmissive) sensor
2: Sensor not used.
Place in separate data stream sent to the printer.
EXAMPLE
<ESC>A
<ESC>IG1
<ESC>Z
OUTPUT
This command does not result in printer output.
NOTES
When the power is cycled, the value set by this command is lost and replaced by the default value
stored in the EEPROM.
To change the value stored in the EEPROM, use the Printer Setting (<ESC>PC) command.
The sensor type may also be set by the use of DSW2-2. The setting priority is determined by the
priority setting in the LCD,