SATO D508 Service Manual Page 224

  • Download
  • Add to my manuals
  • Print
  • Page
    / 290
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 223
Unit 6: Bi-Directional Communications
E/Pro Programming Reference
6-6 PN: 9001096E
COUNTER STATUS (ME)
Receipt of SOH followed by ME causes the printer to return information bounded by an STX-ETX pair that reports
the operating status of the printer’s life counters.
SENSOR STATUS (SG)
Receipt of SOH followed by SG causes the printer to return information bounded by an STX-ETX pair that reports
the current operating status of the printer’s sensors.
20-21 HEX: 00 to 3E7
HEX: FFFF to FC19
Vertical Base Reference Point Offset (0 to 792 dots)
Vertical Base Reference Point Offset (-1 to -792 dots)
22-23 HEX: 00 to 320
HEX: 00 to FCE0
Horizontal Base Reference Point Offset (0 to 800 dots)
Horizontal Base Reference Point Offset (-1 to -800 dots)
24 HEX: 00 to 63
HEX: FF to 9D
Not Supported
25 HEX: 00 to 63
HEX: FF to 9D
Not Supported
26 HEX: 00 to 63
HEX: FF to 9D
Not Supported
27 HEX: 00 to 63
HEX: FF to 9D
Dispense Offset (0 to 99 dots)
Dispense Offset (-1 to -99 dots)
28 Compatibility Mode 00: Enabled
01: Disabled
29 08 to 40 Not Supported
30 Buzzer 00: Enabled
01: Disabled
PARAMETERS
BYTE VALUE DESCRIPTION
1-8 HEX Current Life Counter in dots
9-12 HEX 1st (Current) Head Counter in dots
13-16 HEX 2nd (Previous) Head Counter in dots
17-20 HEX 3rd Head Counter in dots
21-24 HEX Not Supported
25-28 HEX Not Supported
PARAMETERS
BYTE VALUE DESCRIPTION
1 HEX Reflective Sensor Level
2 HEX Transmissive Sensor Level
PARAMETERS
BYTE VALUE DESCRIPTION
Page view 223
1 2 ... 219 220 221 222 223 224 225 226 227 228 229 ... 289 290

Comments to this Manuals