Unit 3: Code Quick Reference
E/Pro Programming Reference
3-6 PN: 9001096E
BKaabbcddeeefffnn...n PDF417. Prints PDF417 2-D symbols.
aa = Minimum module dimension (03-09 dots). Will not print for values of 01,
02 or greater than 09
bb = Minimum module pitch dimension (04-240 dots). Will not print for values
of 01, 02, 03 or greater than 25
c = Security level (1-8)
dd = Code words per line (01-30). If 00 is specified for dd and ee, printer will
automatically optimize settings
ee = Rows/symbol (00 or 03). If 00 is specified for dd and ee, printer will
automatically optimize settings
fff = Number of characters to be encoded (0001-2700)
g = Not specified, standard PDF417
M: Micro PDF417
T: Truncated PDF417
nn...n = Data to be printed.
BLabbcccn...n UPC-A barcode (No HRI). Specifies UPC-A Barcode with start and end bar in the same
length with guard bar.
a = Barcode type: H: UPC-A (“H” fixed)
b = Narrow bar width: Valid range: 01 to 12 dots
c = Barcode height: CG200 Series: 001 to 999 dots
n = Print data: Data: 11 digits fixed
BL ~d UPC-A barcode (Font designation). Specifies font type of UPC-A (with HRI characters).
a = Barcode type: H: UPC-A (“H” fixed)
b = Narrow bar width: Valid range: 01 to 12 dots
c = Barcode height: CG200 series: 001 to 999 dots
n = Print data: Barcode data: 11 digits fixed
d= Font
XU (CG200 Series only)
XS (CG200 Series only)
XM (CG200 Series only)
XB (CG200 Series only)
XL (CG200 Series only)
OA
OB
U* (CG200 Series only)
S* (CG200 Series only)
M* (CG200 Series only)
WB* (CG200 Series only)
WL* (CG200 Series only)
n = Print data: Interpretation data: 12 digits fixed
COMMAND QUICK REFERENCE