SATO D508 Service Manual Page 74

  • Download
  • Add to my manuals
  • Print
  • Page
    / 290
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 73
Unit 4: Standard Command Codes
E/Pro Programming Reference
4-22 PN: 9001096E
MIRROR IMAGE
FUNCTION
To allow mirror image printing of data, such as on transparent labels to be applied to a glass
or other transparent surface.
FORMAT
<ESC>RM
Place after the label data.
EXAMPLE
Label #1
<ESC>A
<ESC>A1<ESC>H0100<ESC>V0050<ESC>XL0ABCDEF
<ESC>RM
<ESC>Q1
<ESC>Z
OUTPUT
(4-14)
NOTES
The <ESC>A1 Media defines the area to be mirrored.
This command can be used with the Rotate Fixed Base Reference Point (<ESC>%) command. Note
that the reference point rotation is dependent upon the location of the <ESC>% command in the data
stream.
This command should not be specified more than once in any single job.
This command cannot be used with commands requiring re-editing of the print area, such as
Sequential Numbering, Real time clock or Copy Image Area.
Any data outside the area defined by the Media Size (<ESC>A1) command is not mirrored the
command is treated as a command error. Any print job containing the <ESC>RM command and
without any print data will be treated as a command error.
Page view 73
1 2 ... 69 70 71 72 73 74 75 76 77 78 79 ... 289 290

Comments to this Manuals

No comments