SATO CL608VA Operator's Manual Page 116

  • Download
  • Add to my manuals
  • Print
  • Page
    / 256
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 115
Job ID Store
Command Structure <ESC>IDaa
aa = Job ID assigned (01 to 99)
Example: <ESC>ID09
Placement: Immediately following the <ESC>A in the job data stream.
Default: None
Command Function To add an identification number to a job. The status of the job can
then be determined using the ENQ command in the Bi-Com status
mode (See Section 5: Interface Specifications for more information).
Printer Input
<ESC>A
<ESC>ID02
. . . Job . . .
<ESC>Z
Printer Output There is no printer output as a result of this command.
Special Notes 1. Works only in Bi-Com mode. The Job ID number must be stored
before Bi-Com status mode can be used.
2. If more than one ID number is sent in a single job, i.e.
<ESC>A
<ESC>ID01
..........
<ESC>ID02
.........
the last number transmitted will be used.
Section 4. Programming Reference
Page 4-469001035 Rev. ESATOCL SeriesPrinters
Page view 115
1 2 ... 111 112 113 114 115 116 117 118 119 120 121 ... 255 256

Comments to this Manuals

No comments