UPC-E
Command Structure <ESC>BEbbccc (data)
<ESC>DEbbccc (data)
bb = Width of narrow element in dots (01-03)
ccc = Bar height in dots (001-600)
(data) = Bar code data (numeric); must be exactly 6 digits
Character Set 0-9 (numeric only)
Density Table
Printer
Model
Value of “bb” Narrow Bar
Width (mils)
Magnification
Factor
CL412
CL612
02 6.7 Below Minimum
03 10.0 75%
04 13.3 100%
CL408
CL608
02 10.0 75%
03 15.0 112%
04 20.0 150%
Notes Command DE provides guide bars that extend longer than the rest of
the bar code.
Example
<ESC>H0400<ESC>V0550<ESC>DE03100123456
<ESC>H0375<ESC>V0600<ESC>OB0
<ESC>H0408<ESC>V0655<ESC>OB123456
Appendix B: Bar Code Specifications
SATOCLSeriesPrinters9001035Rev.EPageB-13