Print Darkness
Command Structure <ESC>#Ea
a = Print darkness value
(see Note 2 for allowable setting)
Example: <ESC>#E2
Placement: Must be placed immediately after <ESC>A and
immediately before <ESC>Z in its own separate data stream
Default: See Note 2
Command Function To specify a new print darkness setting. This command allows
software control of the darkness setting for unique media and ribbon
combinations.
Input to Printer
<ESC>A
<ESC>#E2
<ESC>Z
Printer Output There is no printer output for this command.
Special Notes 1. This becomes the new setting in the printer configuration for all
subsequent print jobs, unless changed. The setting is stored in
non-volatile memory and is not affected by cycling power.
2. The allowable Print Darkness settings for each printer are as
follows:
CL408 CL412 CL608 CL612
Darkness
Settings
1, 2, 3, 4, or 5 1, 2 or 3
Default values are shown in bold type.