POTENTIOMETER ADJUSTMENTS CL608 and CL612
DISPLAY
This potentiometer is used to adjust the contrast of the LCD display for optimum
viewing under various lighting conditions.
POTENTIOMETER ADJUSTMENTS CL408 and CL412
SENSOR THRESHOLD
This potentiometer is operational only if the Label Dispense Option is installed. It is
used to set the Label Taken Sensor threshold. For information on making this
adjustment, see Appendix D: Accessories.
HEX DUMP DIAGNOSTIC LABELS ALL MODELS
In addition to the User Test Print Labels (see page 2-37), the printer contents of the
receive and print buffers can be examined using the Hex Dump Test Labels.
Print Buffer Hex Dump
The contents of the Print Buffer can be examined using the Hex Dump mode. The
label numbers each line of data received in the left-hand column, the data in
hexadecimal format in the center columns followed by the same data in ASCII format
in the right-hand column.
1. Turn the printer on.
2. Send and print label.
3. Place the printer in the Off Line mode by pressing the LINE key. The LINE LED
should go out.
4. Place DSW2-4 in the On position.
5. Press the LINE key to place the printer back in the On Line status.
6. Press the FEED key.
7. A label should be printed containing the contents of the print buffer in Hexadecimal
format.
8. Return DSW2-4 to the Off position.
9. Turn the printer off and then back on to place it back in the normal print mode.
Receive Buffer Hex Dump
The data that is being received by the printer (before it is placed in the Print Buffer)
can be examined by using the Hex Dump Mode. The label numbers each line of
Section 2. Installation and Configuration
SATOCL Series Printers9001035 Rev. EPage 2-41