Unit 4: Standard Command Codes
E/Pro Programming Reference
4-120 PN: 9001096E
OPTION WAITING TIME
FUNCTION
Specifies waiting time for option operations.
FORMAT
<ESC>TWaaa
aaa = Waiting time for option operation =
Valid range: 005 to 200 (unit: 100 ms)
EXAMPLE
Waiting time for option operation = 1.5 seconds
<ESC>A
<ESC>TW015
<ESC>Z
OUTPUT
This command does not result in printer output.
NOTES
This command specifies, in Tear-off mode, the waiting time between print completion and
Tear-off motion.
The set parameter becomes valid soon after receiving the command and will be retained
after power off.