SATO D508 Service Manual Page 217

  • Download
  • Add to my manuals
  • Print
  • Page
    / 290
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 216
Unit 5: Optional Command Codes
E/Pro Programming Reference
5-25 PN: 9001096E
FIELD REGISTER SPECIFICATION
FUNCTION
To register the item inside of the field at the Format Register Specification <ESC>/N.
FORMAT
<ESC>/N,aa,n...n
a = Field number (1 to 99)
n = Print digit number (1 to 99)
EXAMPLE
<ESC>A
<ESC>CC1
<ESC>YS,01
<ESC>/N,1,3
<ESC>%0<ESC>V100<ESC>H200<ESC>P2<ESC>L0101<ESC>XMABC
<ESC>/N,2,5
<ESC>%0<ESC>V300<ESC>H40<ESC>B40208049123456
<ESC>Z
OUTPUT
This command does not result in output. Refer to <ESC>YR Format/Field Recall command.
NOTES
Specify the field number with the order start from the small value.
Print Vertical Position Specification <ESC>V and Print Horizontal Position Specification <ESC>H shall
be specified at every field. It will become default value if none of the specification is made.
When specifying foreign characters using foreign character code <ESC>H, a foreign character needs
four digits (three foreign characters equals twelve digits).
When specifying foreign characters using foreign character code <ESC>B, a foreign character needs
two digits (three foreign characters equals six digits).
Specify the register digit numbers of fixed field out of value 00.
Use this command as a pair with Format Register Specification <ESC>YS.
Due to memory limitations, it may not be able to 99 items.
Page view 216