Unit 5: Optional Command Codes
E/Pro Programming Reference
5-18 PN: 9001096E
BMP FILE, STORE
FUNCTION
To store for printing a graphic file in a BMP format in the optional Expanded Memory.
FORMAT
<ESC>GTaaa,bbbbb,nn...n
aaa = Storage number (001 to 999)
bbbbb = Size of BMP file in bytes
nn..n+ = Data
Place within its own data stream specifying the placement of the graphic.
EXAMPLE
<ESC>A
<ESC>CC1<ESC>GT001, 12345, nn...n
<ESC>Q1<ESC>Z
OUTPUT
There is no printer output as a result of this command.
NOTES
This command requires the Expanded Memory Option. See your SATO representative for details.
Data must be sent in binary format.
The Memory Area Select Command <ESC>CCa must be sent before this command.
The first 62 bytes of the stored file is used for the header and the remainder is the BMP image data.
The graphic will not be printed correctly if the specified size does not match the actual graphic size.
Only black and white non-compressed BMP files can be stored. Color BMP files will cause an error.
If you try to store an image in a memory area that already contains data, an error will occur.