SATO D508 Service Manual Page 106

  • Download
  • Add to my manuals
  • Print
  • Page
    / 290
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 105
Unit 4: Standard Command Codes
E/Pro Programming Reference
4-54 PN: 9001096E
CODE128
FUNCTION
Specifies CODE128 barcode.
FORMAT
<ESC>BGaabbbn~n
a = Narrow bar width (01 to 12 dots)
b = Barcode Height (001 to 999 dots)
n=
Print Data (barcode data and subset shift codes)
Place anywhere after <ESC>V but before <ESC>Q.
EXAMPLE
<ESC>H0200<ESC>V0550<ESC>BG03100>GAB>B789>C123456
<ESC>H0310<ESC>V0665<ESC>XSAB789123456
OUTPUT
(4-35)
NOTES
Specify Start Code at the head of the data.
(1) Start Code A = <ESC>G
(2) Start Code B = <ESC>H
(3) Start Code C = <ESC>I
When using “Start Code C”, specify the print data in even numbered digits.
When the print data contains an odd number of digits, specify “Start Code A” or B” to change the first
character of the print data.
Examples:
1) 15 digits [123456789012345]
<ESC>B1<ESC>C23456789012345
2) 9 digits/Alphanumeric 6 digits [123456789ABC123]
<ESC>C12345678<ESC>B9ABC123
If using “Start Code C” to specify an odd numbered digit, “0” will be added to the end of the print data
before printing.
When a Start Code is omitted, data will be printed with “Start Code B”.
Shift codes are used to change the subset type within the barcode data. Shift codes:
E Subset A Shift Code
D Subset B Shift Code
C Subset C Shift Code
Refer to Appendix: Reference Table 16 for additional information.