Unit 4: Standard Command Codes
E/Pro Programming Reference
4-45 PN: 9001096E
STORE 24X24 DOTS EXTERNAL CHARACTER
FUNCTION
Register external character of 24x24 dots in memory card.
FORMAT
<ESC>T2abbn~n
a=
Data type =
H: Hex character
B: Binary code
b=
Registration font code address
<ESC>JIS
H: “21” to “7F” Up to 95 registries
B: 21H to 7FH Up to 95 registries
<ESC>Shift JIS
H: “40” to “9E” Up to 95 registries
B: 40H to 9EH Up to 95 registries
n=
External character data
EXAMPLE
<ESC>A
<ESC>CC1
<ESC>T2H2100FF00FF 3C0000FF
<ESC>Q2
<ESC>Z
OUTPUT
NOTES
1. Existing data can be overwritten.
2. The Card Slot <ESC>CC command must be sent prior to this command.
3. An error may occur due to capacity shortage when this command and other
commands related to registration are used at the same time. In such a case,
you need to store the data on another card or replace the card with a card of
larger capacity.
4. Data will be out in the order as shown in the Output illustration above.
External file 24 x 24
D1 D2 D3
D4 D5 D6
D7 D8 D9
D70 D71 D72
Page view 96