RESET
If the custom Protocol Command codes are incorrect or if the printer does not
respond to commands using the custom set, the Alternate Protocol Control Codes can
be restored by the following procedure:
1. Turn the printer off.
2. Place DIP switch DS2-7 in the ON position.
3. Turn power on while simultaneously pressing the FEED and LINE switches.
4. When the message “ALT PROTOCOL DEFAULT COMPLETED” appears on the
display, turn the printer off.
5. When the printer is powered up again, the Alternate Protocol Command Code set
will be active. All previous custom settings will be lost.
DOWNLOAD PROCEDURE
The procedure for downloading a custom Protocol Command Code set is:
1. Reset the printer to the default settings using the Reset procedure.
2. Place DIP switch DS2-7 in the ON position.
3. Turn the POWER switch ON while simultaneously pressing the LINE switch. This
places the printer in the USER DOWNLOAD mode.
4. Set DIP switch DS2-7 in the position to accept the Protocol Control codes to be
used for downloading (i.e. DS2-7 = OFF for Standard codes and DS2-7 ON to use
the Alternate set).
5. Press the LINE key to place the M-8485S in the ON-LINE mode. The LINE LED
should be on and the printer is ready to receive the download command data
stream.
6. After the command has been sent, the unit will beep and print a status label. If it
does not beep and print the label, the printer did not accept the data.
7. If the printer does not beep and print a setting label, turn the printer off, check your
download command stream for errors and start the download process over at
step 1.